Line 23: Line 23:
  
 
:Replacement micro has restored sensible temperature readings --[[User:Artag|Artag]] 11:53, 13 July 2012 (UTC)
 
:Replacement micro has restored sensible temperature readings --[[User:Artag|Artag]] 11:53, 13 July 2012 (UTC)
 +
 +
[[Category:Projects]]

Latest revision as of 15:19, 3 June 2013

Hackspace Prusa 3D Printer

Donated to the space by Billy, to be completed / repaired as a group effort.

Mailing list article thread


Jobs

Find/buy stepper motors

Print remaining parts

Listed at Prusa/Parts_List

Make heated bed

Repair Sanguinololu board

I've got the boards (a sanguinololu v1.2 with 4 drivers and one opto limit switch).
Heard from Hipster that the problem was with the temperature measurement. It looks as though the ADC inputs are damaged (the design offers no protection, the microcontroller inputs are directly exposed to external connections) as they're being forced to 2.5V by the micro. Replacement micro ordered. A workaround is possible (use spare ADC inputs) but the micro is cheap.--Artag 06:49, 8 July 2012 (UTC)
Replacement micro has restored sensible temperature readings --Artag 11:53, 13 July 2012 (UTC)