Difference between revisions of "Project:Subatomic metrology"

From London Hackspace Wiki
Jump to navigation Jump to search
(Created page with " == Summary: == A project to acquire the nessassery apparatus and knowhow to allow for the meaningful study radioactivity and subatomic particles in general. == equipment...")
 
Line 4: Line 4:
 
== Summary: ==
 
== Summary: ==
  
A project to acquire the nessassery apparatus and knowhow to allow for the meaningful study radioactivity and subatomic particles in general.
+
A project to acquire the necessary apparatus and knowledge to allow for the meaningful study radioactivity and subatomic particles in general.
  
  
 
== equipment ==
 
== equipment ==
  
One of the main standards in electronic equipment intended for study of nuclear phenomimum is the NIM or nuclear instrumintation module.  These are basicly a slender box with a standard power connector on the rear which slots into a chassis known as a NIM bin or creat.  There is a vast array of NIMs available to perform numerious electronic functions from the very spesific to the quite generic.  The advantage of this system are twofold. First, extreme flexibility it afforded by the modular nature of the system.  Secondly this is an old standard and as such NIMs often come up on ebay for not too hidious prices.  though some of these may be quite old, they are usualy made to extremely high standards with very high quality conponents, making repair a worthwhile option.
+
One of the main standards in electronic equipment intended for study of nuclear phenomena  is the NIM or nuclear instrumentation module.  These are basically a slender box with a standard power connector on the rear which slots into a chassis known as a NIM bin or creat in a maner similar to server blades in a blade chassis.  There is a vast array of NIMs available to perform numerous electronic functions from the very specific to the quite generic.  The advantage of this system are twofold; First, extreme flexibility it afforded by it's modular nature.  Secondly this is an old standard that has been in use for a long time and as such NIMs often come up on ebay for not too hideous prices.  Though some of these may be quite old, they are usually made to extremely high standards with very high quality components, making repair a worthwhile option.
  
NIM bins would commonly consume about 6U in a 19" rack, however i have a slightly smaller one, capible of housing 7 NIMs which should be enough to get us started.  I also have a basic set of NIMs whith which to populate it, a HV PSU, a counter/timer, signal amplifier and rate meter.
+
NIM bins would commonly consume about 6U in a 19" rack, however I have a slightly smaller one, capable of housing 7 single width NIMs which should be enough to get us started and not consume more space than necessary.  I also have a basic set of NIMs with which to populate it, a HV PSU, a counter/timer, signal amplifier and rate meter. The bin i will donate to the space, my NIMs at this stage i am providing on the basis of a 'semi-permanent loan' (basicaly until I leave London)
  
 
I will also be providing a somewhat decrepit NaI:Tl scintillation counter and a thin window GM tube
 
I will also be providing a somewhat decrepit NaI:Tl scintillation counter and a thin window GM tube
Line 18: Line 18:
 
== equipment required: ==
 
== equipment required: ==
  
The main thing we are lacking is a multichannel analyzer, this apparatus digitizes pulses generated by a detector and presents them as a histogram of pulse height (and therefore radiation energy) against occourence thus generating a spectra of the energy of radiation.   
+
* The main thing we are lacking is a multichannel analyser, this is an apparatus that digitizes pulses generated by a detector and presents them as a histogram of pulse height (and therefore radiation energy) against number of pulses received thus generating a spectra of the energy of radiation incident upon the detector.   
  
A better scintilator would be nice, my chunk of NaI is going cloudy ;(  
+
* A better scintilator would be nice, my chunk of NaI is going cloudy ;(  
  
more NIMs are always good... you can't have too many!  
+
* More NIMs are always good... you can't have too many!  
 +
 
 +
* Any CAMAC kit.  (CAMAC is a newer version of NIMs with a backplane. would be nice play with!)
  
  
  
 
== Proposed uses: ==
 
== Proposed uses: ==
investigation of radioactivity in common and novel items
+
* Investigation of radioactivity in common and uncommon items
determination of radionuclide present in items by analysis of decay (e.g chunks of rock)
+
* Determination of radionuclide content items by analysis of decay (e.g chunks of rock)
investigation of novel detector materials, growing of scintillation crystals, novel semiconductor detectors
+
* Investigation of novel detector materials, growing of scintillation crystals, novel semiconductor detectors
investigation of anthropogenic background radiation and cosmic background.
+
* Investigation of anthropogenic background radiation and cosmic background.
 +
 
  
 
== Training required: ==
 
== Training required: ==
  
due to the complexity and flexibility of the NIM system, some training will be required to enable proper operation.  
+
Due to the complexity and flexibility of the NIM system, some training will be required to enable proper operation.  
 
High voltages are required for many of the sensors involved.
 
High voltages are required for many of the sensors involved.
the thin window GM tube is *extremely* fragile and somewhat irreplaceable so *please* be carefull with it.
+
The thin window GM tube is *extremely* fragile and somewhat irreplaceable so *please* be carefull with it.

Revision as of 21:04, 22 February 2013


Summary:

A project to acquire the necessary apparatus and knowledge to allow for the meaningful study radioactivity and subatomic particles in general.


equipment

One of the main standards in electronic equipment intended for study of nuclear phenomena is the NIM or nuclear instrumentation module. These are basically a slender box with a standard power connector on the rear which slots into a chassis known as a NIM bin or creat in a maner similar to server blades in a blade chassis. There is a vast array of NIMs available to perform numerous electronic functions from the very specific to the quite generic. The advantage of this system are twofold; First, extreme flexibility it afforded by it's modular nature. Secondly this is an old standard that has been in use for a long time and as such NIMs often come up on ebay for not too hideous prices. Though some of these may be quite old, they are usually made to extremely high standards with very high quality components, making repair a worthwhile option.

NIM bins would commonly consume about 6U in a 19" rack, however I have a slightly smaller one, capable of housing 7 single width NIMs which should be enough to get us started and not consume more space than necessary. I also have a basic set of NIMs with which to populate it, a HV PSU, a counter/timer, signal amplifier and rate meter. The bin i will donate to the space, my NIMs at this stage i am providing on the basis of a 'semi-permanent loan' (basicaly until I leave London)

I will also be providing a somewhat decrepit NaI:Tl scintillation counter and a thin window GM tube


equipment required:

  • The main thing we are lacking is a multichannel analyser, this is an apparatus that digitizes pulses generated by a detector and presents them as a histogram of pulse height (and therefore radiation energy) against number of pulses received thus generating a spectra of the energy of radiation incident upon the detector.
  • A better scintilator would be nice, my chunk of NaI is going cloudy ;(
  • More NIMs are always good... you can't have too many!
  • Any CAMAC kit. (CAMAC is a newer version of NIMs with a backplane. would be nice play with!)


Proposed uses:

  • Investigation of radioactivity in common and uncommon items
  • Determination of radionuclide content items by analysis of decay (e.g chunks of rock)
  • Investigation of novel detector materials, growing of scintillation crystals, novel semiconductor detectors
  • Investigation of anthropogenic background radiation and cosmic background.


Training required:

Due to the complexity and flexibility of the NIM system, some training will be required to enable proper operation. High voltages are required for many of the sensors involved. The thin window GM tube is *extremely* fragile and somewhat irreplaceable so *please* be carefull with it.