* 25ul total PCR reaction volume - 5ul template (1ul for PC), 2.5ul each forward & reverse primers, 12.5ul Taq readymix, 2.5ul dH20 (6.5ul for PC)
* 25ul total PCR reaction volume - 5ul template (1ul for PC), 2.5ul each forward & reverse primers, 12.5ul Taq readymix, 2.5ul dH20 (6.5ul for PC)
* Initial D - 96C 5 mins, then 35 cycles of D-96C 1 min, A-55C 30 secs, E-72C 1 min.
* Initial D - 96C 5 mins, then 35 cycles of D-96C 1 min, A-55C 30 secs, E-72C 1 min.
[[File:gel12feb2013.JPG|left|400px|thumb|none|Gel 12 Feb]]
[[File:gel12feb2013.jpg|left|400px|thumb|none|Gel 12 Feb]]
* 15ul of samples loaded, 3ul loading buffer, 7ul of ladder loaded.
* 15ul of samples loaded, 3ul loading buffer, 7ul of ladder loaded.
'''From left (after 40 mins at 80V:)'''
'''From left (after 40 mins at 80V:)'''
Line 569: Line 569:
*3: Pip PCR product (nothing)
*3: Pip PCR product (nothing)
*4: A PCR product (band)
*4: A PCR product (band)
*5: J PCR product (faint band)
*5: J PCR product (very faint band)
*6: PC PCR product (band)
*6: PC PCR product (band)
*7: Lui gDNA (nothing)
*7: Lui gDNA (nothing)
*8: Pip gDNA (band)
*8: Pip gDNA (strong band)
*9: A gDNA (faint band)
*9: A gDNA (faint band)
*10: J gDNA (band)
*10: J gDNA (band)
Line 580: Line 580:
'''Conclusions:'''
'''Conclusions:'''


* Lui's extraction didn't contain enough liquid after boiling step, so he added more water afterwards and mixed. This could be responsible for extraction failure.