=== Status ===
=== Status ===
'''NOT IN SERVICE'''
Working, and insured for carrying people.


=== Intro ===
=== Intro ===
This is an electromechanical goods and people lift.
This is an electromechanical goods and people lift in [[447 Hackney Road]]


=== Specs ===
=== Specs ===


* Rated for 4 tonnes
* Designed and installed by: Marryat & Scott of Hounslow
* Made/installed May 1975
* Lift/valve controller: Verac of Manchester Part No: P708
* Internal dimensions of car:
* Pressure Relief Valve Setting: 65kg/cm3 / 950 psi
* Rated: 4 tonnes (55 people apparently)
* Made/installed: 17th September 1976
* Internal dimensions of car: 2.7m x 1.2m


=== Logbook ===
=== Logbook ===


* 2013-03-15 - Lift has oil leak. Needs cleaned up to identify source and how bad the leak is [[User:Tgreer@tsone.info|Tgreer@tsone.info]] ([[User talk:Tgreer@tsone.info|talk]])
* 2013-03-15 - Lift has oil leak. Needs cleaned up to identify source and how bad the leak is [[User:Tgreer@tsone.info|tgreer]] ([[User talk:Tgreer@tsone.info|talk]])
* 2013-03-16 - Lift has been powered off to stop people using it [[User:Tgreer@tsone.info|Tgreer@tsone.info]] ([[User talk:Tgreer@tsone.info|talk]])
* 2013-03-16 - Lift has been powered off to stop people using it [[User:Tgreer@tsone.info|tgreer]] ([[User talk:Tgreer@tsone.info|talk]])
* 2013-03-18 - Russ has contacted insurance brokers to arrange inspection [[User:Tgreer@tsone.info|tgreer]] ([[User talk:Tgreer@tsone.info|talk]])
* 2013-03-28 - Lift has been inspected. Note that there are two faults : a slight leak from a valve in the equipment room which is of little concern, and a leak in the shaft. This is a leak from the left-hand ram and has caused a small puddle. Lift engineers are fetching lighting, cleaning and inspecting to determine whether to replace a seal. This repair is expected to be paid for by the landlord.  [https://pointless.net/photos/id/1364479613/] [https://pointless.net/photos/id/1364479702/] [https://pointless.net/photos/id/1364479733/ pictures] [[User:artag|artag]] reporting jasperw from conversation on irc
* 2013-06-25 - Lift inspected with Russ. No oil leaking from cylinders for now.
 
 
[[Category:Outdated Pages]]

Latest revision as of 18:51, 21 October 2021

Status

Working, and insured for carrying people.

Intro

This is an electromechanical goods and people lift in 447 Hackney Road

Specs

  • Designed and installed by: Marryat & Scott of Hounslow
  • Lift/valve controller: Verac of Manchester Part No: P708
  • Pressure Relief Valve Setting: 65kg/cm3 / 950 psi
  • Rated: 4 tonnes (55 people apparently)
  • Made/installed: 17th September 1976
  • Internal dimensions of car: 2.7m x 1.2m

Logbook

  • 2013-03-15 - Lift has oil leak. Needs cleaned up to identify source and how bad the leak is tgreer (talk)
  • 2013-03-16 - Lift has been powered off to stop people using it tgreer (talk)
  • 2013-03-18 - Russ has contacted insurance brokers to arrange inspection tgreer (talk)
  • 2013-03-28 - Lift has been inspected. Note that there are two faults : a slight leak from a valve in the equipment room which is of little concern, and a leak in the shaft. This is a leak from the left-hand ram and has caused a small puddle. Lift engineers are fetching lighting, cleaning and inspecting to determine whether to replace a seal. This repair is expected to be paid for by the landlord. [1] [2] pictures artag reporting jasperw from conversation on irc
  • 2013-06-25 - Lift inspected with Russ. No oil leaking from cylinders for now.