Cabinet Wiring: Difference between revisions
From London Hackspace Wiki
Line 113: | Line 113: | ||
| || Example || Vacuum pump || switched mains supply | | || Example || Vacuum pump || switched mains supply | ||
|- | |- | ||
| J8 || 1 || Example || | | J8 || 1 || Example || RED estop | ||
|- | |- | ||
| || 2 || Example || | | || 2 || Example || RED estop | ||
|- | |- | ||
| || | | || 3 || Example || WHITE Guard switch and door lock | ||
|- | |- | ||
| || | | || 4 || Example || PURPLE Guard switch and door lock | ||
|- | |- | ||
| || | | || 5 || Example || BLACK Guard switch and door lock | ||
|- | |- | ||
| || | | || 6 || Example || BROWN Guard switch and door lock | ||
|- | |- | ||
| || | | || 7 || Example || YELLOW Guard switch and door lock | ||
|- | |- | ||
| || 8 || Example || RED Guard switch and door lock | |||
| || 8 || Example || | |||
|- | |- | ||
| J9 || Example || front panel switch || vacuum pump control | | J9 || Example || front panel switch || vacuum pump control |
Revision as of 12:03, 14 March 2022
Original (Baldor) interface wiring
No obvious connector numbering on the board, so these are numbered clockwise starting from the bottom right hand corner (power) with pins numbered consecutively in the same direction - ie pin 1 to pin n run clockwise.
Connector | pin | destination | description |
---|---|---|---|
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Example | Example | Example | Example |
Estop / power relay board
Connector and pin numbering taken from File:Schematic Design MRP-0850B.pdf
Connector | pin | destination | description |
---|---|---|---|
J1 | 1 | mains filter | mains in to relay board |
Example | Example | Example | |
Example | Example | Example | |
J2 | Example | mains transformer | in/out windings |
Example | Example | Example | |
Example | Example | Example | |
J3 | Example | n/c | AC LV supply out |
Example | Example | Example | |
J4 | Example | Bridge rectifier | AC out / DC in |
Example | Example | Example | |
J5 | Example | Example | AC |
Example | Example | Example | |
J6 | Example | control board | DC power out to controller |
Example | Example | Example | |
J7 | Example | VFD | switched mains supply |
Example | VFD | switched mains supply | |
Example | Vacuum pump | switched mains supply | |
Example | Vacuum pump | switched mains supply | |
J8 | 1 | Example | RED estop |
2 | Example | RED estop | |
3 | Example | WHITE Guard switch and door lock | |
4 | Example | PURPLE Guard switch and door lock | |
5 | Example | BLACK Guard switch and door lock | |
6 | Example | BROWN Guard switch and door lock | |
7 | Example | YELLOW Guard switch and door lock | |
8 | Example | RED Guard switch and door lock | |
J9 | Example | front panel switch | vacuum pump control |
Example | Example | Example | |
J10 | 1 | controller J8 | WHITE input ?? disable Z axis brake when low |
2 | Example | GREY input enable vacuum pump when low | |
3 | Example | input unlock door when low | |
5 | Example | estop | |
6 | Example | estop | |
Example | Example | Example | Example |
J11 | 1 | controller J3 | GREY |
2 | controller J3 | GREY | |
3 | controller J3 | PURPLE | |
4 | controller J3 | PURPLE | |
J12 | 1 | brake actuator | releases z axis brake when energised |
2 | brake actuator | 0V | |
4 | brake actuator | +24 | |
J13 | 1 | J13 pin 4 | link |
2 | VFD pin 1,2 | spindle enable | |
3 | VFD pin 1,2 | spindle enable | |
4 | J13 pin 1 | link | |
5 | control board J7 | input grounded to energise (release) Z axis brake |
Spindle drive (Baldor VS1ST)
Connector | pin | destination | description |
---|---|---|---|
1 | 1 | Power board | +24V out |
2 | Power board | D IN 1 - connect to to pin 1 to enable drive | |
6 | Control board | An IN 1 - speed control voltage | |
7 | Control board | 0V | |
10 | estop chain | Relay contacts n/o | |
11 | estop chain | Relay contacts n/o |