Archive:CALMU3

From London Hackspace Wiki
No edit summary
Line 72: Line 72:
|
|
<code>
<code>
BAA3123B
*"BAA3123B"
BV182B85
*"BV182B85"
BW918D2F
*"BW918D2F"
Bv05B6CE
*"Bv05B6CE"
Bw01B525
*"Bw01B525"
</code>
</code>
|-
|-
Line 83: Line 83:
|
|
<code>
<code>
I1+15.230
* "I1+15.230"
I2+0.0000
* "I2+0.0000"
I3-0.0300
* "I3-0.0300"
</code>
</code>
|-
|-
Line 92: Line 92:
|
|
<code>
<code>
K1+2.0700
* "K1+2.0700"
K2+0.0000
* "K2+0.0000"
K3+0.0100
* "K3+0.0100"
KA+2.0600
* "KA+2.0600"
KV-1.3300
* "KV-1.3300"
KW+1.6300
* "KW+1.6300"
</code>
</code>
|-
|-
Line 104: Line 104:
|
|
<code>
<code>
L1+9.0200
* "L1+9.0200"
L2+0.0100
* "L2+0.0100"
L3+0.0200
* "L3+0.0200"
</code>
</code>
|-
|-
Line 113: Line 113:
|
|
<code>
<code>
P1+1.6400
* "P1+1.6400"
P2-0.0000
* "P2-0.0000"
P3+0.0000
* "P3+0.0000"
</code>
</code>
|-
|-
Line 122: Line 122:
|
|
<code>
<code>
Q1=0.769-
* "Q1=0.769-"
Q2=1.000+
* "Q2=1.000+"
Q3=1.000+
* "Q3=1.000+"
QA=0.787-
* "QA=0.787-"
</code>
</code>
|-
|-
Line 132: Line 132:
|
|
<code>
<code>
UA=2631984
* "UA=2631984"
UV=0349470
* "UV=0349470"
UW=2549220
* "UW=2549220"
Uv=0177551
* "Uv=0177551"
Uw=0000001
* "Uw=0000001"
</code>
</code>
|-
|-
Line 143: Line 143:
|
|
<code>
<code>
V1+236.75
* "V1+236.75"
V2+240.72
* "V2+240.72"
V3+242.45
* "V3+242.45"
</code>
</code>
|-
|-
Line 152: Line 152:
|
|
<code>
<code>
i1-5.6300
* "i1-5.6300"
i2-0.0000
* "i2-0.0000"
i3-0.0100
* "i3-0.0100"
</code>
</code>
|-
|-
Line 161: Line 161:
|
|
<code>
<code>
p1-1.3400
* "p1-1.3400"
p2+0.0000
* "p2+0.0000"
p3-0.0100
* "p3-0.0100"
</code>
</code>
|-
|-
Line 170: Line 170:
|
|
<code>
<code>
UA=2631986
* "UA=2631986"
UV=0349470
* "UV=0349470"
UW=2549221
* "UW=2549221"
Uv=0177552
* "Uv=0177552"
Uw=0000001
* "Uw=0000001"
</code>
</code>
|-
|-

Revision as of 16:56, 6 November 2010

Calmu3 (possibly Calmu3+) from Polymeters Response International. "The first microprocessor-based meter", using "FFT, rather than 'brute-force' DSP" [1]

I think I read somewhere that Calmu3 (minus the +) lacks CoP5 approval.

It may need calibration periodically, but that's probably up to the supplier.

Details

  • Serial no: P99A01869
  • Part no: C3DBD0BC0SJ (3 phase direct, class 1 accuracy, lithium backup, ?)

Interfaces

Software with support


Resources

A later model, with overview.

Presumably ex-PRI consultant on Calmu meters


Serial protocol

1200bps ASCII, \r terminated

Equals symbols are shown on some variables, but presumably wouldn't fit for many.

Once a 'N', 's', 'u' or 'x' are matched, all the remainder of the line is ignored. This suggests they might be for switching to a different protocol, or buggy code. 'u' is definitely buggy.

Commands

F Frequency, updated per sample "F=50.138\r"
N Switch protocol? ff
R (Real?) time "R=15:00:40\r"
S Serial number (presumably "=" doesn't fit) "SP99A01869\r"
s ? "s=", dword 0xa605019e, dword 0, "\r"
u (probably unimplemented) "U\r"
x Switch protocol? ff
B[AVWvw] ?

  • "BAA3123B"
  • "BV182B85"
  • "BW918D2F"
  • "Bv05B6CE"
  • "Bw01B525"

I[123] Current

  • "I1+15.230"
  • "I2+0.0000"
  • "I3-0.0300"

K[123AVW] ?

  • "K1+2.0700"
  • "K2+0.0000"
  • "K3+0.0100"
  • "KA+2.0600"
  • "KV-1.3300"
  • "KW+1.6300"

L[123] Load?

  • "L1+9.0200"
  • "L2+0.0100"
  • "L3+0.0200"

P[123] ?

  • "P1+1.6400"
  • "P2-0.0000"
  • "P3+0.0000"

Q[123A] ?

  • "Q1=0.769-"
  • "Q2=1.000+"
  • "Q3=1.000+"
  • "QA=0.787-"

U[AVWvw] Units

  • "UA=2631984"
  • "UV=0349470"
  • "UW=2549220"
  • "Uv=0177551"
  • "Uw=0000001"

V[123] Voltage

  • "V1+236.75"
  • "V2+240.72"
  • "V3+242.45"

i[123] Current?

  • "i1-5.6300"
  • "i2-0.0000"
  • "i3-0.0100"

p[123] ?

  • "p1-1.3400"
  • "p2+0.0000"
  • "p3-0.0100"

u[AVWvw] ?

  • "UA=2631986"
  • "UV=0349470"
  • "UW=2549221"
  • "Uv=0177552"
  • "Uw=0000001"

?

Showing 1 related entity.