Calmu3 (possibly Calmu3+) from Polymeters Response International. "The first microprocessor-based meter", using "FFT, rather than 'brute-force' DSP" [1]
I think I read somewhere that Calmu3 (minus the +) lacks CoP5 approval, but the picture in the manual shows the same as ours.
It may need calibration periodically, but that's probably up to the supplier.
Details
- Serial no: P99A01869
- Part no: C3DBD0BC0SJ (3 phase direct, class 1 accuracy, lithium backup, C?)
Interfaces
- Infrared PACT port (this is a standard - possible adapter)
- Serial port ("for PC, modem or PACTLAN")
Software with support
- Principal (DOS) or Ease II (can't get this to run on XP due to .vbx; probably needs 2000; uses stopcopy protection) from PRI
- mv-rs, and possibly other Itron stuff
- Ziphany http://www.ziphany.com/Files/Supported_Meters.pdf
Resources
A later model, with a nice overview of available metrics.
Presumably ex-PRI consultant on Calmu meters
Serial protocol
1200bps ASCII, \r terminated
Equals symbols are shown on some variables, but presumably wouldn't fit for many.
Once a 'N', 's', 'u' or 'x' are matched, all the remainder of the line is ignored. This suggests they might be for switching to a different protocol, or buggy code. 'u' is definitely buggy.
Commands
F | Frequency, updated per sample | "F=50.138\r"
|
---|---|---|
N | Switch protocol? | ff
|
R | (Real?) time | "R=15:00:40\r"
|
S | Serial number (presumably "=" doesn't fit)
|
"SP99A01869\r"
|
s | ? | "s=", dword 0xa605019e, dword 0, "\r"
|
u | (probably unimplemented) | "U\r"
|
x | Switch protocol? | ff
|
B[AVWvw] | ? |
|
I[123] | Current |
|
K[123AVW] | ? |
|
L[123] | Load? |
|
P[123] | ? |
|
Q[123A] | ? |
|
U[AVWvw] | Units |
|
V[123] | Voltage |
|
i[123] | Current? |
|
p[123] | ? |
|
u[AVWvw] | ? |
|
? |
|