Equipment/PCB etch station
Status
We are currently planning on fixing-up the unit and working out how it should be configured:
From a quick test it appears to have no major faults : it heats all the tanks, it bubbles, the spray wash solenoids click, and the tanks don't appear to leak. And the cupboard turned out to contain some developer and tin plating crystals!
The tanks are currently full of water - very polluted by the previous contents. Don't expect it to etch ! The intention is to soak off the old contents, clean them out and then refill.
The bench should be usable in the simplest form as soon as we've checked it out, but there are some things we can do to make the best of it. There's a need for a handful of plumbing and electrical accessories.
Do NOT put water in the spray washes (the unlidded tanks between the main tanks) at the moment. These have open drains leading into a pipe that currently goes nowhere - so they'll dump water on the floor. What's supposed to happen is that the cold inlet can be turned on (with spray buttons on the front panel), and the wash water runs straight out the drain, they do not fill up like the main tanks.
Todo
Urgent
- Check tank drains (clamped tubes inside cupboard) to make sure clamps and tubes are sound and not just about to fail.
- Check bubble bar carefully for an even flow : replace water in etch tank with clean, use torch to see if all holes are bubbling. If it's not fairly even, clean as described by Mike on the mailing list (but note warnings about damaging clamping nuts). If there are only minor problems with the bubble bar, try cleaning without removing (prick holes with pin, use cleaning crystals, run bubbler etc.). Warning - the bubble bar will only operate when the heater is on, and there MUST be plenty of water in the tank to operate the heater
- Flush all tanks another couple of times, scrubbing top area back into the water.
- Fill and use if desired
Soon
- Scrub out sink
- Connect waste pipe on back of cabinet. There are some random plumbing fittings in a bag in the cupboard and may be some more in the space, possibly under the lab 24 sink. In particular a rodding tee that was fitted to the outlet, and a new swept tee. Check under the hangar 23 sink for a spot to link in using that swept tee or some other fittings. A length of 1 1/4" pipe will be needed and maybe a few other fittings.
- Connect cold water to wash tanks. This can probably be done using the tap just above the tank, if the pipes are long enough. BUT DON'T DO THIS UNTIL THE WASTE IS CONNECTED!!
- Build splashback if possible.
- Connect cold water to tap. Might be possible using a Y connector on the same supply as the wash tank, but a neater solution would be to add washing machine fittings to the side of the existing sink unit. Unfortunately there's a water heater in the cupboard just where you need to work.
- Connect hot water to tap. Probably not really needed since there's an adjacent sink, but would complete the job.
Usage configuration
- Since it's already stained there's no problem in putting ferric chloride in it if we have some available (it needs 5 litres but 3 or 4 would do).
- We can use a spare tank to start brewing the cupric chloride if we want to do that
- I (artag) have some of Mega's good developer I can use to set up a development tank
- I have some date-expired mask stripper we can try in a strip tank
- Mega also sell some ferric chloride cleaner at £16 for a kg. Might be worth a go.
- This is apparently Oxalic acid. There may be a cheaper source, eg builder's merchants.
Placement
- We need water and waste connections for the rinse tanks. These are simple washing machine fittings but we may need adapters for the supply pipework and a waste hose. I do have some plumbing fittings but we may need more.
- Depending on when you need these, I could go out and get these on Fri/Sat. -- Elliot
- I think we'll need at least one cold fitting, ideally another cold and a hot too, and a way to get 1.25" waste into the sink plumbing - possibly just a length of pipe, possibly some joints. May be easiest to put things in place and then find exactly what's needed.
- Where do we put it ? I suggested replacing the unit 23 sink, but short-term it could simply go next to it. Tools may need moving, though. Or it could be installed in the unit 23 toilet. Or it could be integrated into a darkroom build. Discuss ..
- I think it can fit next to the sink in the place of the metal cabinet that is there currently - it may be a bit longer and deeper but that shouldn't be a problem. Ideally it'd be nice to keep the sink for other chemical type experiments. If we can avoid talking about the darkroom then we can save ourselves a lot of hassle :-) -- Elliot.
- It would be nice to have power without using the extension lead. The existing ring main might be extended fairly easily to put sockets on the wall near the sink.
- Again, depending on when electrical stuff is needed, I could go out and get conduit/socket/back box/etc. on Fri/Sat. -- Elliot
- I see there's a bit of conduit near #23 back door. Needs a socket plate and probably some more 2.5mm wire to link into the ring. Could be patched up but a better plan might be to look at fixing a couple of electrical jobs and buy the bits at the best price rather than in small pieces.
Model
Instructions
The tank was previously in school and there is a laminated sheet with usage instructions. It may not be applicable to our use but is worth looking at.
Heater and bubble bar Maintenance - also see Mike's posting on mailing list.
Fine etch crystals - we don't use this at present but it's been suggested.
[http://www.megauk.com/datasheets/5185_Data_Sheet_Immerse_Tin_(600-020-021).pdf - We have a small tub of this, possibly unusably old.