Difference between revisions of "LBL04007"

From London Hackspace Wiki
Jump to navigation Jump to search
(Removed autoclave top-up procedure as this is now in LBL08002)
Line 1: Line 1:
  
  
== Using the Kill Bin" ==
+
== Using the Kill Bin ==
 
{| class="wikitable"
 
{| class="wikitable"
 
|Author: wzdd
 
|Author: wzdd
Line 17: Line 17:
 
'''1. Purpose'''
 
'''1. Purpose'''
  
 
+
This describes the protocol for use of the Kill Bin, which is a beach-filled container used for the inactivation and disposal of biological waste and lab equipment which may have become biologically contaminated.
  
 
'''2. Scope'''
 
'''2. Scope'''
Line 34: Line 34:
  
 
'''7. Procedures'''
 
'''7. Procedures'''
 +
 +
7.1 Refilling the Kill Bin
 +
 +
The bin should contain a mixture of 60% bleach and 40% water.
 +
  
 
'''8. Resources'''
 
'''8. Resources'''

Revision as of 22:15, 3 December 2014


Using the Kill Bin

Author: wzdd Approved by: S. Thompson SOP No. LBL04007
Signed: Signed: Effective from:
Date: Date: Last edited:

1. Purpose

This describes the protocol for use of the Kill Bin, which is a beach-filled container used for the inactivation and disposal of biological waste and lab equipment which may have become biologically contaminated.

2. Scope


3. Responsibilities


4. Materials

5. Related documents


6. Definitions


7. Procedures

7.1 Refilling the Kill Bin

The bin should contain a mixture of 60% bleach and 40% water.


8. Resources