We don't use the alarm controller, but we do use the 12V UPS and sensors for the [[Door control system|door controller]].  The UPS model number is 1381N.
 
We don't use the alarm controller, but we do use the 12V UPS and sensors for the [[Door control system|door controller]].  The UPS model number is 1381N.
 +
 +
* 1 amp output, 1.5 amp maximum (including battery charging)
 +
* Mains LED (green) indicates that mains is connected. Extinguishes if disconnected from mains or mains input fuse is blown.
 +
* Battery Stand-by LED (amber) indicates that unit is operating on battery stand-by. (does it? It's on all the time. seems to mean the battery is fine, unplugging the mains certainly powers the circuits off the battery, and the battery can't have been powering it the entire time...)
 +
* Output Fault (red) indicates that output fuse fault or battery fuse fault. Further LED (red) on PCB shows battery fuse failure.
 +
  
 
* [http://www.elmdene.co.uk/products/downloads/N%20Range-I2.pdf UPS data sheet]
 
* [http://www.elmdene.co.uk/products/downloads/N%20Range-I2.pdf UPS data sheet]

Revision as of 20:22, 26 July 2010

Landlord

The centre manager is Ted Kerr (07730 200 260).

Phone Service

There are two phone lines in the space. Only one is connected - the number is 020 7613 5391. Phone service is provided through M-Line, who are a great little BT reseller. Any problems, ring them up and ask for Strachan (pronounced straw-n). Say Russ Garrett sent you.

Networking

Internet is provided by Be - we have the Be Pro service on a 1 year contract (started 18/07/2010), with Annex-M.

IP:      93.97.176.250
Netmask: 255.255.248.0
Gateway: 93.97.176.1
DNS 1:   87.194.255.154
DNS 2:   87.194.255.154

The BeBox is operating in bridged mode with all routing handled by the Fonera.

Our internal network operates on the 172.31.24.0/23 range (this is registered with ChaosVPN).

We also advertise and route IPv6 within the space. This is currently tunnelled to Hurricane Electric. The account is currently with Mark, but will be transferred shortly.

IP prefix: 2001:470:92f1::/48

We do not use DHCP for IPv6 at the moment, so do not provide automatic rDNS. Servers are set up for DNS under hack.rs, which is also currently with Mark.

The switch is a 3CR17501-91

Electricity

Initial meter reading: 251818 (16/07/2010)

Alarm

We don't use the alarm controller, but we do use the 12V UPS and sensors for the door controller. The UPS model number is 1381N.

  • 1 amp output, 1.5 amp maximum (including battery charging)
  • Mains LED (green) indicates that mains is connected. Extinguishes if disconnected from mains or mains input fuse is blown.
  • Battery Stand-by LED (amber) indicates that unit is operating on battery stand-by. (does it? It's on all the time. seems to mean the battery is fine, unplugging the mains certainly powers the circuits off the battery, and the battery can't have been powering it the entire time...)
  • Output Fault (red) indicates that output fuse fault or battery fuse fault. Further LED (red) on PCB shows battery fuse failure.