Tools

node id name battery backup lock type RFID module PCB PSU MAC Address IPv4 Addr Status Notes Card cache MQTT Topic Base Software Door release
1 back doorbot 7Ah SLA Gianni EB300 solenoid bolt Elechouse NFC module v3 acnode/doorbot board in enclosure, mains fed 00:1a:b6:03:03:47 In Service RAM /door/gf-back Installed and active
3 LulzBot_Hull nil n/a Elechouse NFC module v4 wire wrap in enclosure, wall wart 00:1A:B6:02:B2:18 10.0.40.3 In Service SSR eeprom /tool/hull
4 LulzBot_Crump nil n/a Elechouse NFC module v3 acnode board rev 2 in enclosure, wall wart 00:1A:B6:02:BF:6F 10.0.40.4 In Service SSR in tool itself eeprom /tool/crump
5 Ground floor doorbot 7Ah SLA Gianni EB300 solenoid bolt Elechouse NFC module v4 acnode shield rev 4, also acnode board rev 2 for pinouts 00:1A:B6:02:F3:F5 10.0.40.5 In Service built into same enclosure as Front Doorbot. RFID reader to be placed on glass door RAM /door/gf-front-inner Installed and active
6 Front doorbot 7Ah SLA landlord's maglock, remote relay release Deek-Robot acnode shield rev 4, also acnode board rev 2 for pinouts 00:1A:B6:03:12:F4 10.0.40.6 In Service Landlord's maglock, powered by landlord's PSU, installed relay to interrupt. Door release is Landlord's, with timed release via their door entry system RAM /door/gf-front-external N/A - landlord's door release
8 Biolab restricted doorbot 7Ah SLA Elechouse NFC module v4 acnode shield rev 4, also acnode board rev 2 for pinouts 90:A2:DA:00:F3:C3 10.0.40.8 In Service Shared enclosure and PSU with back gate cage doorbot RAM /door/gf-biolab Installed and active
10 Radio room restricted doorbot 7AH SLA maglock Deek-Robot acnode shield rev 4, also acnode board rev 2 for pinouts in enclosure 00:1A:B6:03:44:BF In Service in same enclosure as Electronics Room doorbot RAM /door/1f-funk (because "radio" is cooler in german) Installed and active
11 lasercutter nil n/a Elechouse NFC module v4 acnode board rev 2 POE splitter 00:1A:B6:02:CB:75 10.0.40.11 In Service SSR in acnode enclosure eeprom /tool/laz0rz
12 Back gate cage doorbot maglock Elechouse NFC module v4 acnode/doorbot board 00:1a:b6:02:d9:4b 10.0.40.12 In Service Shared enclosure and PSU with biolab doorbot sdcard /door/gf-backgate Installed and active
13 Hopper nil n/a LHS vending machine board Vending Machine. Under construction Neither door, nor tool, registered in acserver as a door n/a
14 SSR only ready for deployment nil acnode board rev 2 single phase AC
15 Colchester Master Lathe nil n/a Deek-Robot acnode/doorbot board POE splitter 00:1a:b6:03:41:51 10.0.40.15 In Service 3-phase but possible single phase low-current control cable numbers 22/23 eeprom /tool/colchester
16 Bridgeport Mill nil n/a Deek-Robot acnode/doorbot board POE splitter 00:1A:B6:03:41:4A 10.0.40.16 In Service Interrupts 110V power to e-stop circuit. acnode powered via PoE eeprom /tool/bridgeport
17 Tool Store 7Ah SLA maglock Elechouse NFC module v4 acnode/doorbot board in enclosure 00:1A:B6:03:52:70 10.0.40.17 In Service built into same enclosure as back doorbot /door/gf-toolstore
18 Sedgwick TA315 Table Saw nil n/a Elechouse NFC module v4 acnode board rev 2 00:1A:B6:02:CD:98 10.0.40.18 In Service single phase AC. 16A commando /tool/sedgwick
Wishlist for acnode/doorbot controlled equipment below here
De Walt Table Saw single phase AC. SSR
Woodworking lathe single phase AC, 13A
19 Planer nil n/a Deek-Robot acnode board rev 2 00:1a:b6:02:cc:d9 10.0.40.19 In Service single phase 16A. SSR
20 Radial Arm Saw nil n/a acnode shield rev 4 00:1A:B6:03:08:0A /tool/ras


If an acnode crashes and is fed by PoE, then try unplugging the network cable and re-plugging it. The indicator LED on the button should rainbow cycle while rebooting.

Items in stock

  • 1x Connected Launchpads
  • 3x 40A SSRs - please don't use
  • 3x RFID Readers
  • 0x RGB LED arcade buttons