Risk Assessment/ Gas Torches

From London Hackspace Wiki
Jump to navigation Jump to search


Risk Assessment - Gas Torches

This risk assessment is intended to provide guidance on the risk associated with the above equipment and activities in normal use. Please also check general risk assessments for the space as a whole. Any discrepancies, errors or concerns should be raised with the document maintainers or trustees - do not edit this assessment directly. For responsible persons and last update, see 'version log' of the assessment page.

Activity

Heating of metals for hot forming, brazing, soldering or similar purposes, using a handheld or stationary torch that uses Propane or Butane fuels

Signage

Understanding Risk Rating

LOW - Ensure current control measures are in place and continue with activity

MED - Control measures may be adequate, co-supervision is recommended

HIGH - Do not undertake activity without further consultation with area specialists

Risk Assessment

Identify Hazards Who May be Harmed and How Severity Control Measures Likelihood Risk Rating
Burns from heat. Users High Operators are competent in the use of the equipment. Fire retardant gloves are to be worn. Hot material is to be treated with care and watched until sufficiently cool as not to pose a fire risk. If the equipment is not in satisfactory working order it should not be used. Medium Medium
Slips Trips and Falls Users, Bystanders Medium Wear shoes or boots with non-slip soles, in particular in wet or snowy weather – make sure excessive wet isn’t tracked into the space. Ensure that good standards of housekeeping are maintained at all times, cables and other equipment will be managed so as not to cause a trip hazard. Medium  Low
Fire from Hot Work Users, bystanders, public High It should be ensured that there is no combustible material in close proximity to the work. Suitable protection should be provided for any combustible items that cannot be moved and for combustible construction such as wooden worktops. A check should be carried out on all of the surrounding areas to minimise the possibility of ignition by heat transfer. Fire extinguishers are be provided in the space. Hot work should be stopped at the specified time before leaving the space. A thorough inspection of the area should be undertaken once the work is complete after completion. Where necessary, a further check should be carried out before leaving the space. Medium   Medium
Use of gas bottles, leaks and high pressure discharge. Users, bystanders, public High Bottles must be secured in the upright position, preferably on a trolley to aid mobility. All gauges, hoses, bagging and torches must be examined before use, any faulty equipment must be repaired or replaced prior to use. Medium    Low