Anonymous

Project:Blood typing: Difference between revisions

From London Hackspace Wiki
adding 16 Jan PCR
(adding 16 Jan PCR)
Line 540: Line 540:


== PCR (Nicholas, Ben) 16/1/13==
== PCR (Nicholas, Ben) 16/1/13==
* Repeated PCR on successful samples from November 2012.
* Ran PCR with PB1 primers on these two + 1 positive control with SYBR green Taq readymix + 1 PC with Taq readymix
* 25ul total PCR reaction volume - 5ul template (1ul for PC), 2.5ul each forward & reverse primers, 12.5ul SYBR green Taq readymix / Taq readymix, 2.5ul dH20 (6.5ul for PC)
* Initial D - 96C 5 mins, then 35 cycles of D-96C 1 min, A-55C 30 secs, E-72C 1 min.
* PCR left overnight. 7ul of samples loaded, 7ul of ladder loaded. (Less than previous times)
* Ran electropheresis with new, larger power source, with constant 80V.
* After 5 mins: bands were initially visible, especially ladder, Ben, and PC.
* After 40 mins: We left it for too long, and the bands had disappeared.  No photo taken.
'''Notes:'''
We could work on a better visualisation system.  Currently using black pouch as background.
The gel bath has broken, we will try a plastic food container next time.
The main button on the smaller pipette has broken, super glue needed.
17

edits