Heating: Difference between revisions

From London Hackspace Wiki

Line 16: Line 16:
The wiring diagram inside the connection cover appears to show a capacitor-start motor with a centrifugal switch, but there is no obvious switch. It would be reasonable to assume some of the internal wiring is to a switch, but the connections shown are open circuit. Furthermore, if they were to a switch, it would turn the motor off once it got to speed.
The wiring diagram inside the connection cover appears to show a capacitor-start motor with a centrifugal switch, but there is no obvious switch. It would be reasonable to assume some of the internal wiring is to a switch, but the connections shown are open circuit. Furthermore, if they were to a switch, it would turn the motor off once it got to speed.


I'm guessing that it's not a centrifugal switch, but a thermal fuse. So the mains input is actually on Z2/U1 as shown on Tec's data sheet, but goes via V1/V2 to match the cover diagram. The fuse has blown for reasons unknown.
I'm guessing that it's not a centrifugal switch, but a thermal fuse. So the mains input is actually on Z2/U1 as shown on Tec's data sheet, but goes via V1/V2 to match the cover diagram. The fuse has expired for reasons unknown.