Anonymous

Brain hackers: Difference between revisions

From London Hackspace Wiki
no edit summary
mNo edit summary
No edit summary
Line 7: Line 7:




-EEG -> multiple copies of the 1 channel bipolar (TrueSense Kit) recorder, multiple copiMindWave Mobile (1 channel), Emotiv Epoc (14 channels), KT88 (16 channels, photoic stimulation), AMEA slow potentials mapper (2 channels), new model of AMEA expected Feb
-EEG -> multiple copies of the 1 channel bipolar (TrueSense Kit) recorder, multiple copies of MindWave Mobile (1 channel), Emotiv Epoc (14 channels), KT88 (16 channels, photoic stimulation), AMEA slow potentials mapper (2 channels), new model of AMEA expected this year




Line 13: Line 13:




-tACS (transcranial alternate current stimulation) -> DIY, DrTES (transcranial analgesia device)  
-tACS/tPCS (transcranial alternate current stimulation) -> DIY, foc.us, DrTES (transcranial analgesia device)  




Line 19: Line 19:




-Weak field TMS (transcranial magnetic stimulation, microtesla range or even lower) -> 64 coil Koren helmet augmented for placement of more coils, smaller phone tap coils - based hats and setups, large (3m) coil, MIT-MT stimulator (0.1-99 Hz range) with different size coils (induction going up to 25 mT max, 8-shaped configuration up to 10 mT) including coils with centrally positioned high power red, infrared and blue LEDs for combined ligfht and magnetic stimulation
-Weak field TMS (transcranial magnetic stimulation, microtesla range or even lower) -> 64 coil Koren helmet augmented for placement of more coils, smaller phone tap coils - based hats and setups, large (3m) coil, MIT-MT stimulator (0.1-99 Hz range) with different size coils (induction going up to 25 mT max, 8-shaped configuration up to 10 mT) including coils with centrally positioned high power red, IR and blue LEDs for combined light/photic and magnetic stimulation




-Other -> SGR sensor, photopletismograph, modulated high voltage "singing arc", scopes, magnetometers, function generators, amps etc.  
-Other -> SGR sensor, photopletismograph with vegetative status estimation capability, modulated high voltage "singing arc", scopes, magnetometers, function generators, amps etc.  


Of course, you are more than welcome to suggest other relevant ideas to test and projects to try. The possibilities are, indeed, "Limitless" (pun intended).
Of course, you are more than welcome to suggest other relevant ideas to test and projects to try. The possibilities are, indeed, "Limitless" (pun intended).