Brain hackers: Difference between revisions

From London Hackspace Wiki

m
no edit summary
m (Kit updates)
mNo edit summary
Line 14: Line 14:


-tACS/tPCS (transcranial alternate current stimulation) -> DIY, foc.us, thync, Rhythm-2 2 channel tPCS stimulation device, DrTES (transcranial analgesia device)  
-tACS/tPCS (transcranial alternate current stimulation) -> DIY, foc.us, thync, Rhythm-2 2 channel tPCS stimulation device, DrTES (transcranial analgesia device)  


-Transcranial laser / decoherent light stimulation within optical permeability window of tissues (roughly between 600 and 1200 nm) -> Matrix LLLT with in-built photometer and external biofeedback block, impulse modulated 890 nm and 635 nm single and matrix lasers, continuous modulated 810 and 640 nm, all-inclusive large laser/LED combining heads
-Transcranial laser / decoherent light stimulation within optical permeability window of tissues (roughly between 600 and 1200 nm) -> Matrix LLLT with in-built photometer and external biofeedback block, impulse modulated 890 nm and 635 nm single and matrix lasers, continuous modulated 810 and 640 nm, all-inclusive large laser/LED combining heads


-High Power TMS (short pulses up to 1 Tesla, modulation 2-2500 Hz) - TDHP40DEL with 4 coils.   
-High Power TMS (short pulses up to 1 Tesla, modulation 2-2500 Hz) - TDHP40DEL with 4 coils.   


-Weak field TMS (transcranial magnetic stimulation, microtesla range or even lower) -> 64 coil Koren/Murphy/Persinger helmet augmented for placement of more coils, smaller phone tap coils - based hats and setups, large (3m) coil, MIT-MT stimulator (0.1-99 Hz range) with different size coils (induction going up to 30 mT max, 8-shaped configuration up to 10 mT) including coils with centrally positioned high power red, IR and blue LEDs for combined light/photic and magnetic stimulation, Almag-02 Version 2 running field (up to 50 mT) pre-programmed multi-coil stimulator, Gefest peripheral feedback 4-coil stimulator (tissue impedance - modulated low frequency fields up to 10 mT)
-Weak field TMS (transcranial magnetic stimulation, microtesla range or even lower) -> 64 coil Koren/Murphy/Persinger helmet augmented for placement of more coils, smaller phone tap coils - based hats and setups, large (3m) coil, MIT-MT stimulator (0.1-99 Hz range) with different size coils (induction going up to 30 mT max, 8-shaped configuration up to 10 mT) including coils with centrally positioned high power red, IR and blue LEDs for combined light/photic and magnetic stimulation, Almag-02 Version 2 running field (up to 50 mT) pre-programmed multi-coil stimulator, Gefest peripheral feedback 4-coil stimulator (tissue impedance - modulated low frequency fields up to 10 mT)


- SHF - Aquaton weak (microwatt range) SHF stimulator (1.001 GHz that can be modulated at 0.1, 8 and 16 Hz) with an external antenna
- SHF - Aquaton weak (microwatt range) SHF stimulator (1.001 GHz that can be modulated at 0.1, 8 and 16 Hz) with an external antenna


-Other -> photopletismograph with vegetative status estimation capability, modulated high voltage "singing arc", scopes, magnetometers, function generators, amps, shielded random number generator etc.  
-Other -> photopletismograph with vegetative status estimation capability, modulated high voltage "singing arc", scopes, magnetometers, function generators, amps, shielded random number generator etc.