Brain hackers: Difference between revisions

From London Hackspace Wiki

1,346 bytes added ,  23 January 2016
m
no edit summary
mNo edit summary
mNo edit summary
Line 4: Line 4:




'''''List of kit available by different members of the group:'''''
'''''List of measurement and stimulation kit available by different members of the group:'''''




-EEG -> multiple copies of the 1 channel bipolar (TrueSense Kit) recorder, multiple copies of MindWave Mobile (1 channel) and Muse (4 channels), Emotiv Epoc (14 channels), KT88 (16 channels, photic stimulation), AMEA slow potentials mapper (2 channels)
-EEG -> multiple copies of the 1 channel bipolar (TrueSense Kit) sensor, multiple copies of MindWave Mobile (1 channel) and Muse (4 channels), Emotiv Epoc+ (14 channels), KT88 (16 channels, photic stimulation), AMEA slow potentials mapper (2 channels)  




Line 22: Line 22:




-Weak field TMS (transcranial magnetic stimulation, microtesla range or even lower) -> 64 coil Koren/Murphy/Persinger helmet augmented for placement of more coils, smaller phone tap coils - based hats and setups, large (3m) coil, MIT-MT stimulator (0.1-99 Hz range) with different size coils (induction going up to 30 mT max, 8-shaped configuration up to 10 mT) including coils with centrally positioned high power red, IR and blue LEDs for combined light/photic and magnetic stimulation, Almag-02 Version 2 running field (up to 50 mT) pre-programmed multi-coil stimulator, Gefest peripheral feedback 4-coil stimulator (tissue impedance - modulated low frequency fields up to 10 mT)
-Weak field TMS (transcranial magnetic stimulation, microtesla range or even lower) -> 64 coil Koren/Murphy/Persinger helmet augmented for placement of more coils, smaller phone tap coils - based hats and setups, large (3m) coil, MIT-MT stimulator (0.1-99 Hz range) with different size coils (induction going up to 30 mT max, 8-shaped configuration up to 10 mT) including coils with centrally positioned high power red, IR and blue LEDs for combined light/photic and magnetic stimulation, MIT-11 stimulator with coils similar to MIT-MT but different induction and frequency step settings, Almag-02 Version 2 running field (up to 50 mT) pre-programmed multi-coil stimulator, Gefest peripheral feedback 4-coil stimulator (tissue impedance - modulated very low (> 1 Hz) frequency fields up to 10 mT)




- SHF - Aquaton weak (microwatt range) SHF stimulator (1.001 GHz that can be modulated at 0.1, 8 and 16 Hz) with an external antenna
- SHF - Aquaton weak (microwatt range) SHF stimulator (1.001 GHz that can be modulated at 0.1, 8 and 16 Hz) with an external antenna
- Ultrasound: MIT-11 stimulator supports 44 kHz 2-5 mkm amplitude ultrasound which can be modulated from 0 to 99.9 Hz with a 0.1 Hz step.




Line 31: Line 34:




DIY news: USB fully software-controlled 2 channel combined electro/TMS/infrared stimulator is now fully operational, PoC code that internetworks BCI's from various vendors will be available soon - it already works on Macs with Mindwave and Muse.  
DIY news:  
- USB fully software-controlled 2 channel combined electro/TMS/infrared stimulator is now fully operational, new version that will also support a DC component is on the way.
- PoC code that internetworks BCI's from various vendors will be available soon - it already works on Macs with Mindwave and Muse.  
- We have obtained an intranasal electrode which can be used both for electrostimulation of medial prefrontal cortex and nootropics electrophoresis. Will start experimenting with electrophoresis of 20 % Piracetam soon
 
 
Miscellanea:
Michael Persinger's "God Helmet" effectiveness has been reproduced by an independent group: http://www.scribd.com/doc/267811996/God-Helmet-Replication-Study
Possible step towards CEMI: http://www.sciencedaily.com/releases/2016/01/160114121806.htm




Miscellanea: Michael Persinger's "God Helmet" effectiveness has been reproduced by an independent group: http://www.scribd.com/doc/267811996/God-Helmet-Replication-Study
Politics:
Some of us actively stand for excluding nootropics, ergotropics and adaptogenes from this Bill together with the rest of http://www.transhumanistparty.org.uk/ - 
see https://www.newscientist.com/article/2074813-youre-not-hallucinating-mps-really-did-pass-crazy-bad-drug-law/
First they ban enhancing substances, and then go after the devices! Join the campaign if you are not indifferent.




Line 81: Line 95:


http://www.newstatesman.com/lifestyle/2015/07/hacking-brain-can-diy-neuroscience-make-you-happier-and-smarter
http://www.newstatesman.com/lifestyle/2015/07/hacking-brain-can-diy-neuroscience-make-you-happier-and-smarter
Somewhat confused report at CNN Money:
http://money.cnn.com/video/technology/2015/12/02/london-brain-hacker.cnnmoney
About our Brain Hacking stand at the Lisbon Maker Faire Sept 2015:
http://nerri.eu/eng/news-highlights/nerri-news/hacking-the-brain-at-lisbon-maker-faire.aspx


We've got a chapter on the near future of accessible neurostimulation in  
We've got a chapter on the near future of accessible neurostimulation in