Line 261: | Line 261: | ||
|- | |- | ||
| || 6 || motor || YELLOW | | || 6 || motor || YELLOW | ||
|} | |||
{| class="wikitable" | |||
|+ DIP switch config X,Y,Z axes | |||
|- | |||
! Switch !! function !! setting | |||
|- | |||
| 1 || dynamic current || on 5.6A peak, 4A RMS | |||
|- | |||
| 2 || || on | |||
|- | |||
| 3 || || on | |||
|- | |||
| 4 || standstill current || off 1/2 dynamic current | |||
|- | |||
| 5 || || on 20 microsteps/step / 4000 microsteps/rev | |||
|- | |||
| 6 || || off | |||
|- | |||
| 7 || || on | |||
|- | |||
| 6 || || off | |||
|} | |||
{| class="wikitable" | |||
|+ DIP switch config 4th axis | |||
|- | |||
! Switch !! function !! setting | |||
|- | |||
| 1 || dynamic current || on 5.6A peak, 4A RMS | |||
|- | |||
| 2 || || on | |||
|- | |||
| 3 || || on | |||
|- | |||
| 4 || standstill current || off 1/2 dynamic current | |||
|- | |||
| 5 || || on 2 microsteps/step / 400 microsteps/rev | |||
|- | |||
| 6 || || off | |||
|- | |||
| 7 || || on | |||
|- | |||
| 6 || || off | |||
|} | |} |