Cremer st - Infrastructure/Kitchen Wiring: Difference between revisions

From London Hackspace Wiki
(→‎Back-up option: wouldn't actually be a spur)
m (→‎Back-up option: but this would)
Line 30: Line 30:
=== Back-up option ===
=== Back-up option ===
* 2x4mm runs, one for hob, one for oven
* 2x4mm runs, one for hob, one for oven
* Leave boiler on electric circuit or do a separate 2.5/4mm run for that.
* Put boiler on a fused spur or do a separate 2.5/4mm run for that.

Revision as of 23:27, 15 February 2012

People: Russ, Paddyd, Phil

We have sockets and 2.5mm cable aplenty.

Planned

  • Distro box: 3x32A breakers, 1x16A breaker
  • Cables:
Purpose Power Diameter Length
Distro 100A 16mm
Oven 5kW (>>22A) 4mm
Hob 6kW/6.6kW (>>29A) 4mm
Water heater guess 3kW (13A) 2.5mm
Ring main 2.5mm

Upgrade all diameters (2.5-4, 4-6, 16-25) if not clipped to a masonry or wooden wall.

Suggested suppliers

  • TLC-direct (cheap, but whole drum)
  • ?


Back-up option

  • 2x4mm runs, one for hob, one for oven
  • Put boiler on a fused spur or do a separate 2.5/4mm run for that.