Equipment/SPC1601: Difference between revisions
No edit summary |
Mich181189 (talk | contribs) No edit summary |
||
(One intermediate revision by one other user not shown) | |||
Line 2: | Line 2: | ||
| name = PDU <!-- Name of the item. --> | | name = PDU <!-- Name of the item. --> | ||
| image = Hackspace_Unknown.png <!-- Image of the item. Leave with placeholder image if none exists. --> | | image = Hackspace_Unknown.png <!-- Image of the item. Leave with placeholder image if none exists. --> | ||
| model = Avocent | | model = Avocent SPC1620H2 <!-- Model --> | ||
| category = Equipment <!-- Main category. Please leave alone to keep item in this category --> | | category = Equipment <!-- Main category. Please leave alone to keep item in this category --> | ||
| subcat = | | subcat = Defunct <!-- Sub-category if one exists. Please check main listing to see other categories contained within the main one --> | ||
| status = Good working order <!-- Set to one of; Good working order, Faulty, Out of order, Under construction, Out of consumables, Scrapped, or Unknown --> | | status = Good working order <!-- Set to one of; Good working order, Faulty, Out of order, Under construction, Out of consumables, Scrapped, or Unknown --> | ||
| consumables = <!-- Any items used up in normal operation, such as; ink, paper, saw-blades, cutting disks, oil, etc.. --> | | consumables = <!-- Any items used up in normal operation, such as; ink, paper, saw-blades, cutting disks, oil, etc.. --> | ||
Line 51: | Line 51: | ||
[http://www.andovercg.com/datasheets/cyclades-alterpath-pm-pdu-install-guide.pdf Admin manual] | [http://www.andovercg.com/datasheets/cyclades-alterpath-pm-pdu-install-guide.pdf Admin manual] | ||
^- might be the wrong manual. | |||
Default behaviour is to act as a fairly dumb power strip - after a few seconds, all the outputs are turned on in sequence and remain on. | Default behaviour is to act as a fairly dumb power strip - after a few seconds, all the outputs are turned on in sequence and remain on. |
Latest revision as of 22:12, 24 May 2021
This is a 16 port 2U(?) smart power strip connected to the IPKVM box in the rack downstairs. We can use it to power of and on kit in the rack and measure total power consumption of the rack.
current port assignments
- A1: the ipkvm box itself
- A2
- A3
- A4
- B1: the Dlink POE midspan thing
- B2: Asimov
- B3: Babbage
- B4
- C1
- C2
- C3
- C4
- D1
- D2
- D3
- D4
TODO
- Get borg on the pdu
- Get the hp thing on the pdu
- graph power usage
- and loads of other stuff...
Other info
We use the pdu with the ipkvm thing, so this info isn't needed, might come in handy at some point tho.
^- might be the wrong manual.
Default behaviour is to act as a fairly dumb power strip - after a few seconds, all the outputs are turned on in sequence and remain on.
The control connection is RS232 to the RJ45 'IN' connector, as described in table A.19 of the manual above. Pinouts on page 45 of ftp://ftp.avocent.com/public/product-upgrades/SPC/SPC%20Hardware%20Manual.pdf
It doesn't make sense to connect the two DSR pins together. This occurs because in chaining the units, pin 8 is connected anyway by the RJ45 cable and is presumably not used.
Connecting this to a PC running Kermit at 9600 baud, I got an immediate login prompt. The unit I tried had the factory default users set - no groups or usernames, user admin has password pm8. I didn't have to set any special line conditions so it's possible a 3-wire data-only connection would do.
If you need to reset the password, see loopback plug wiring (link pins 1-8, 2-7, 3-6)