Project:LED the Space*: Difference between revisions
(Created page with "Please add comments to the sections below as appropriate General comments Priorities A/ Make lighting "fit for purpose" B/ Reduce power consumption C/ Minimise capital costs...") |
mNo edit summary |
||
Line 13: | Line 13: | ||
A | == A Replacement tubes/starters for existing fluorescent fittings == | ||
Replacement tubes/starters for existing fluorescent fittings | |||
Pros | |||
No changes to existing installation | No changes to existing installation | ||
New lamps should last ~5/10,000 hrs | New lamps should last ~5/10,000 hrs | ||
Line 26: | Line 25: | ||
Fittings may fail soon, they are probably in the last quarter of their life. | Fittings may fail soon, they are probably in the last quarter of their life. | ||
B | == B Replace existing fittings with new, more efficient type of fluorescent (T5 etc.) == | ||
Replace existing fittings with new, more efficient type of fluorescent (T5 etc.) | |||
Pros | Pros | ||
Line 36: | Line 34: | ||
C | == C Replace existing incandescent lamps with CF lamps == | ||
Replace existing incandescent lamps with CF lamps | |||
Pros | Pros | ||
Line 44: | Line 41: | ||
D | == D Replace existing fittings with LED equivalent == | ||
Replace existing fittings with LED equivalent | |||
(Either commercial fittings or "home brewed") | (Either commercial fittings or "home brewed") | ||
Pros | Pros | ||
Line 57: | Line 53: | ||
Sources of Supply | Sources of Supply | ||
London Bulbs Ltd | London Bulbs Ltd |
Latest revision as of 08:58, 27 April 2015
Please add comments to the sections below as appropriate General comments Priorities A/ Make lighting "fit for purpose" B/ Reduce power consumption C/ Minimise capital costs D/ Reduce maintenance
If new fittings are installed alongside the existing (disconnected) ones, on moving out they can be taken with us and the originals re-connected.
Ideas for replacement of existing lighting.
A Replacement tubes/starters for existing fluorescent fittings
Pros No changes to existing installation New lamps should last ~5/10,000 hrs Inexpensive No specialist skills needed
Cons Power consumption remains high Fittings may fail soon, they are probably in the last quarter of their life.
B Replace existing fittings with new, more efficient type of fluorescent (T5 etc.)
Pros Reduced consumption New fittings will easily outlast our occupancy of the premises
Cons
C Replace existing incandescent lamps with CF lamps
Pros
Cons
D Replace existing fittings with LED equivalent
(Either commercial fittings or "home brewed") Pros Good , consistent light Low consumption Commercial fittings are complete, reliable and easily installed with minimum effort.
Cons
Sources of Supply
London Bulbs Ltd www.londonbulbs.co.UK
IKEA
(insert URL)
Maplin (insert URL)
etc....