Equipment/ReworkStation: Difference between revisions
No edit summary |
m (→18th Novemver 2014: transposed digits misspelling fixed) |
||
Line 73: | Line 73: | ||
===18th Novemver 2014=== | ===18th Novemver 2014=== | ||
Old KADA | Old KADA 852D was destroyed and has been replaced with a new WEP 852D+ |
Revision as of 16:22, 18 November 2014
Status
Air flow will only start when you remove the nuit from the cradle.
WARNING! Do NOT switch the unit off at the wall when it is still hot otherwise you will destroy the unit. To move the unit, switch off on the front panel and wait until the fan stops and the lights switch off.
The hot air element is said to be easily burnt out at low airflow rates. Presumably the temperature control is not fast enough to turn the heater off in time. Please be careful, especially at low airflow / high heat settings to avoid damage.
Specification
- Make: WEP
- Model: 852D+
Supplies
Tips
- It appears that Kada don't sell tips, you are supposed to use Hakko 900M tips. The last batch bought were these.
Heating elements
The new gun is similar to the old one. The following information may or may not be applicable. Please use with care
- Hot-air elements can be found cheaply on eBay: example 1, example 2. Note that the part for the model 852D is different from that for the 852D+, possibly in the way the connections are made to the cable.
Installation is a little fiddly.
- Undo screws holding handle together
- Pay close attention to the position of plastic plate through which the wires pass. This plate holds the element in the correct position and stops it from shorting out on the metal nozzle.
- Cut away heatshrink sleeving over 2 wires leading to heater
- Unplug bared crimp terminals
- Earth terminal should just unplug if necessary
- Power terminals are soldered as well as pushed together. Heat while unplugging.
- Unplug white plug block (thermistor connection)
- Remove element
- Replace element (teabot, can you add some notes since you found out how do do this right ?)
- Thread new heatshrink sleeving over power wires
- Note that wires are easily confused as both one of the power wires and the earth wire are black. Do not mix these up. Check continuity to earth pin on mains plug if unsure.
- Connect thermistor plug
- Connect power pins. Solder pins together. (I don't know why this is needed but that's how it was ..)
- Replace heatshrink over pins. Note that there is mains voltage on these pins so be careful that the sleeving is undamaged and will not be pinched.
- Reassembly is the reverse of disassembly.
- Hide leftover parts
Log book
9th May 2011 - Elliot
- The earth lead had become detached from the nozzle. This had been spot welded and could not be soldered (the solder would melt). The nozzle was drilled and riveted instead.
- The element was moved further into the nozzle and secured with the internal plastic spacer (this holds the wire and is not near the element). Consequently the element doesn't arc now.
28th April 2011 - Adrian
- Fitted with a new element but this was shorting and blowing a fuse because I had the element too close to the end of the tube. I thought there might be a ceramic spacer at the tip but there wasn't.
- The seller of the replacement element also sells a complete hot-air handle unit which may be required. However, I don't think it's a straight plug-in on the model we have.
18th Novemver 2014
Old KADA 852D was destroyed and has been replaced with a new WEP 852D+