447 Networking
There is a 48 port patch panel in the cab in the office upstairs, of which 29 ports are used.
The Cab has 7 free U, we need 2 for the switches and 1 for Boole leaving 4...
N.B. new plans depend on working out what we need for new classrooms etc.
Our ISP
80/20 FTTC, 1Tb bandwidth/mo with Zen, see speedtest or [1]
We're getting a native IPv6 only ADSL connection thanks to Andrews & Arnold!
IP's
we have a /29 : 82.69.229.0/29, all are aliased on lo on boole see /etc/iptable/rules for forwarding details
WiFi
We have 6 Cisco 3502 Access points, current deployment:
- AP1 - office/quiet room - now mounted properly, thanks User:Sully!
- AP2 - classroom ceiling.
- AP3 -
- AP4 -
- AP5 -
- AP6 - spare
Ground Floor
Existing
- 1 - 2 office near window
- 3 - 4 office under cab
- 5 office under cab - single socket
- 6,7,8,9,10,11,12 - classroom
- 13 - 14 pillar near shower
- 15 - 16 left of roller door
- 17 - 18 rear wall of lobby
- 27 - 28 office under cab
- 29 - office under cab
- 30-36 - classroom
- 37,38 - doorbot
- 39,40 - near door in office
- 41,42 - classroom roof, 24 used for ap2
- +2 more to outside the classroom
4 spaces left on the patch panel!
To be added
Rear Door
Socket needed for doorbot (Wilson) I'd suggest running a double to here done, but may want a direct connection instead.
Quiet room
- 1 x double socket and a quad - maybe not if we put shelving up.
Classroom 2
Ignoreing this for now.
South Wall Outside the Classroom
- quad socket by tesla
- quad socket by the table next to tesla
Both above serve tesla + babbage + printers + other bits
- dual socket on the east side of the electronics bench
- and another on the west side
- dual socket somewhere by the door for future doorbot + other bits <- maybe a quad here?
All the above to go over new trunking, 14 cables.
Classroom
sockets on north and west wallsdone!- East wall: 4 x double socket
- South wall 3 double sockets
all 7 double sockets above to be fed from the trunking on the south side of the horizontal pillar thing along the ceiling == 14 cables, maybe too much to fit?
Basement
Existing
- 19 - 20 on far wall near hose reel and phone dist boards.
- 21 - 22 on wall on outside of lift plant room
- 23 - 24 biohack basement on far wall.
- 25 - 26 near fire hose pumps hidden behind the desk/counter
To be added
- 1 x double socket near biohackers door for ac node/doorbot
- 2 x double socket in each workshop for acnode
- ?
Total new sockets on the ground floor cabinet
4 between ground and basement 14 in the classroom 14 along south wall -- 36
= 32 new ports needed (4 spare on the existing panels).
but 24 ports a panel, so 2nd new panel with 18 free? or restrict ourselves to 28 new ports?
5 doubles in the classroom 1 quad by tesla and babbage 1 double by tesla and babbage 1 quad by the door?
= 20 + 4 to the basement.