Equipment/lobbypdu

From London Hackspace Wiki

Questionable health status after usage in 447 Hackney Road.

  • lobbypdu.lan.london.hackspace.org.uk
  • usernames 'admn' and 'root' should both work
  • Outlet 1 is used for 'fun' things that can be switched of at night, currently the BigClock and Tom's sign in the Lobby
  • Outlet 2 currently unused, could be used for doorbot maybe?
  • n.b. Not on the UPS
  • Although it has 2 ports for temperature and humidity sensors we don't have the actual sensors
  • It doesn't do current monitoring.
  • http://www.servertech.com/products/switched-pdus/switched-pdu-cw-2h-ipm-2
lobbypdu
Hackspace Unknown.png
Model Sentry / Servertech.com CW-2H
Sub-category Defunct
Status Scrapped
Accessories Cat5 patch leads
Training requirement no
Origin Donation?
Location Above the Lobby
Maintainers Sysadmin team

procedures

All on hamming. These are for port 1, for port 2 change the 1.1.1 to 1.1.2

to switch a port on

cd ~jasper/lobbypdu
snmpset -v 2c -M +. -c private lobbypdu .iso.org.dod.internet.private.enterprises.serverTech.sentry3.systemTables.outletTable.outletEntry.outletControlAction.1.1.1 i 1

and off

cd ~jasper/lobbypdu
snmpset -v 2c -M +. -c private lobbypdu .iso.org.dod.internet.private.enterprises.serverTech.sentry3.systemTables.outletTable.outletEntry.outletControlAction.1.1.1 i 2