Cremer st - Infrastructure: Difference between revisions
From London Hackspace Wiki
no edit summary
No edit summary |
No edit summary |
||
| Line 43: | Line 43: | ||
* Description: ... | * Description: ... | ||
* Status: Dismantled and removed from Wet Lab. | * Status: Dismantled and removed from Wet Lab. Fans have been kept for possible future use. | ||
* People: ? | * People: ? | ||
| Line 49: | Line 49: | ||
* Description: ... | * Description: ... | ||
* Status: Clean and tidy, Flushes OK | * Status: Clean and tidy, Flushes OK. Washroom now contains a coat rack for Lab coats, coveralls, aprons etc. | ||
* People: ? | * People: ? | ||
| Line 55: | Line 55: | ||
* Description: for projections | * Description: for projections | ||
* Status: need to obtain epoxy bolts, then put up screen | * Status: <s> need to obtain epoxy bolts,</s> then put up screen | ||
* People: Adrian (?) | * People: Adrian (?) | ||
* Proposal : drill and epoxy bolts into ceiling near window. Drill auxiliary fixings to hold bolts in place while epoxy sets. After setting, | * Proposal : <s>drill and epoxy bolts into ceiling near window. Drill auxiliary fixings to hold bolts in place while epoxy sets. After setting,</s> (done) Perform pull test on bolts. Schedule team of helpers to lift screen into place and fix. These activities will create some dust, mess and brief disruption in the quiet room. | ||
* Requirements : epoxy capsules (I have some of these, possibly date-expired - artag), studding, large masonry drill bit, heavy duty power drill. I also have the latter 2, but can't bring them to the space cleaning day. It may be possible to do the drilling phase before that date. | * Requirements : <s>epoxy capsules (I have some of these, possibly date-expired - artag), studding, large masonry drill bit, heavy duty power drill. I also have the latter 2, but can't bring them to the space cleaning day. It may be possible to do the drilling phase before that date.</s> | ||
Update 4SEP11 | |||
* Progress: Bolts now fixed into ceiling, Mounting plates made and ready. | |||
* Further requirements: Due to revised mounting method more materials as below | |||
**4 off M12 full nuts | |||
**4 off <s>M12 flat washers</s> (on site) | |||
**4 off M10 studding 350mm | |||
**16 off M10 full nuts | |||
**16 off M10 flat washers | |||
**4 off strong hackers to lift screen into place | |||
**2 off weak hackers to fit the nuts | |||
=== Quiet Room Projector === | === Quiet Room Projector === | ||
* Description: replace existing projector with the NEC projector, mount it properly | * Description: replace existing projector with the NEC projector, mount it properly | ||
* Status: New mounting part built, | * Status: New mounting part built, replaces a ceiling tile. Final detail of mount depends upon geometry of projector to be used. | ||
* People: Phil | * People: Phil | ||