*Air conditioning radiator matrix or similar.
*Air conditioning radiator matrix or similar.
*Water pump (for cooling loop).
*Water pump (for cooling loop).
*1" thick aluminium or stainless plate, at least 7 1/4" diameter.
**I have a block of aluminium 250mm sq x 75 mm. a bit wasteful but could be used. artag.
*Clean box section or angle-iron (a push-fit connector frame would be fine too).
*Clean box section or angle-iron (a push-fit connector frame would be fine too).
*1.5-2" thick, ~4" wide sturdy plastic (delrin?) to turn an large threaded fitting for the chamber.
*1.5-2" thick, ~4" wide sturdy plastic (delrin?) to turn an large threaded fitting for the chamber.
Line 103: Line 101:
*debris catch-pot on degasser side).
*debris catch-pot on degasser side).
*Pirani and [[Pledges/Vacuum_Gauge|Penning gauge controllers]].
*Pirani and [[Pledges/Vacuum_Gauge|Penning gauge controllers]].
===Cooling system===
The E04 diffusion pump uses an 850Watt heater. The typical surface temperature will reach upwards of 200c (maximum 250c for pump body, max 400c for pump base).
The pump technical data specifies the maximum water pressure should be 5bar/72.5psi. Minimum water supply temperature should be 10c, and maximum return temperature should be 35c. (presuming return in this case means "water coming back out of the pump cooling jacket")
The minimum flow-rate should 75l/h^-1.
This suggests that the E04 will need a radiator capable of dispersing 2.2Kw of heat (7512BTU). (NEEDS CHECKING)
As the baffle and valve assembly as also have cooling-loops, some additional capacity should be factored in. No numbers exist for these parts however. As they are indirectly heated however and part of reflux prevention, they perhaps should have a secondary cooling loop or auxiliary radiator between them.