Anonymous

Heating: Difference between revisions

From London Hackspace Wiki
663 bytes added ,  1 April 2013
Line 32: Line 32:


  - buy a 1.5kW single phase motor with the correct shaft / pulley and fit it. Check that the previous repair has actually provided single phase power (with neutral) and isn't running the motor across two phases
  - buy a 1.5kW single phase motor with the correct shaft / pulley and fit it. Check that the previous repair has actually provided single phase power (with neutral) and isn't running the motor across two phases
Things we've checked :
Looking at the motor connections on the cover diagram, it's apparent that mains power must flow into V1 for any effect at all. But this connection has a high resistance to all other pins. It's either a burnt out winding, a faulty switch (unlikely, given the connections) or unused wiring (seems surprising, but there are too many wires for a simple single-phase capacitor-run motor).
The capacitor appears to be fine
Things we haven't checked :
There is a wiring diagram on the Tec website for capacitor-run motors which does not use the unconnected V1 pin. Perhaps this is the correct wiring ? But then how did the motor ever work ?