Difference between revisions of "Project:Tool Access Control/Deployment"

From London Hackspace Wiki
Jump to navigation Jump to search
(update from spreadsheet, the old page was way out of date)
 
Line 54: Line 54:
 
== Items in stock ==
 
== Items in stock ==
  
* 0x Connected Launchpads
+
* 1x Connected Launchpads
* 3x 40A SSRs
+
* 3x 40A SSRs - please don't use
 
* 3x RFID Readers
 
* 3x RFID Readers
 
* 0x RGB LED arcade buttons
 
* 0x RGB LED arcade buttons

Latest revision as of 16:28, 15 October 2020

This page is for keeping track of what we need to achieve, and how far along we are to achieving it.


Tools

node id name battery backup lock type RFID module PCB PSU MAC Address IPv4 Addr Status Notes Card cache MQTT Topic Base Software Door release
1 back doorbot 7Ah SLA Gianni EB300 solenoid bolt Elechouse NFC module v3 acnode/doorbot board in enclosure, mains fed 00:1a:b6:03:03:47 In Service RAM /door/gf-back Installed and active
3 LulzBot_Hull nil n/a Elechouse NFC module v4 wire wrap in enclosure, wall wart 00:1A:B6:02:B2:18 10.0.40.3 In Service SSR eeprom /tool/hull
4 LulzBot_Crump nil n/a Elechouse NFC module v3 acnode board rev 2 in enclosure, wall wart 00:1A:B6:02:BF:6F 10.0.40.4 In Service SSR in tool itself eeprom /tool/crump
5 Ground floor doorbot 7Ah SLA Gianni EB300 solenoid bolt Elechouse NFC module v4 acnode shield rev 4, also acnode board rev 2 for pinouts 00:1A:B6:02:F3:F5 10.0.40.5 In Service built into same enclosure as Front Doorbot. RFID reader to be placed on glass door RAM /door/gf-front-inner Installed and active
6 Front doorbot 7Ah SLA landlord's maglock, remote relay release Deek-Robot acnode shield rev 4, also acnode board rev 2 for pinouts 00:1A:B6:03:12:F4 10.0.40.6 In Service Landlord's maglock, powered by landlord's PSU, installed relay to interrupt. Door release is Landlord's, with timed release via their door entry system RAM /door/gf-front-external N/A - landlord's door release
8 Biolab restricted doorbot 7Ah SLA Elechouse NFC module v4 acnode shield rev 4, also acnode board rev 2 for pinouts 90:A2:DA:00:F3:C3 10.0.40.8 In Service Shared enclosure and PSU with back gate cage doorbot RAM /door/gf-biolab Installed and active
10 Radio room restricted doorbot 7AH SLA maglock Deek-Robot acnode shield rev 4, also acnode board rev 2 for pinouts in enclosure 00:1A:B6:03:44:BF In Service in same enclosure as Electronics Room doorbot RAM /door/1f-funk (because "radio" is cooler in german) Installed and active
11 lasercutter nil n/a Elechouse NFC module v4 acnode board rev 2 POE splitter 00:1A:B6:02:CB:75 10.0.40.11 In Service SSR in acnode enclosure eeprom /tool/laz0rz
12 Back gate cage doorbot maglock Elechouse NFC module v4 acnode/doorbot board 00:1a:b6:02:d9:4b 10.0.40.12 In Service Shared enclosure and PSU with biolab doorbot sdcard /door/gf-backgate Installed and active
13 Hopper nil n/a LHS vending machine board Vending Machine. Under construction Neither door, nor tool, registered in acserver as a door n/a
14 SSR only ready for deployment nil acnode board rev 2 single phase AC
15 Colchester Master Lathe nil n/a Deek-Robot acnode/doorbot board POE splitter 00:1a:b6:03:41:51 10.0.40.15 In Service 3-phase but possible single phase low-current control cable numbers 22/23 eeprom /tool/colchester
16 Bridgeport Mill nil n/a Deek-Robot acnode/doorbot board POE splitter 00:1A:B6:03:41:4A 10.0.40.16 In Service Interrupts 110V power to e-stop circuit. acnode powered via PoE eeprom /tool/bridgeport
17 Tool Store 7Ah SLA maglock Elechouse NFC module v4 acnode/doorbot board in enclosure 00:1A:B6:03:52:70 10.0.40.17 In Service built into same enclosure as back doorbot /door/gf-toolstore
18 Sedgwick TA315 Table Saw nil n/a Elechouse NFC module v4 acnode board rev 2 00:1A:B6:02:CD:98 10.0.40.18 In Service single phase AC. 16A commando /tool/sedgwick
Wishlist for acnode/doorbot controlled equipment below here
De Walt Table Saw single phase AC. SSR
Woodworking lathe single phase AC, 13A
19 Planer nil n/a Deek-Robot acnode board rev 2 00:1a:b6:02:cc:d9 10.0.40.19 In Service single phase 16A. SSR
20 Radial Arm Saw nil n/a acnode shield rev 4 00:1A:B6:03:08:0A /tool/ras


If an acnode crashes and is fed by PoE, then try unplugging the network cable and re-plugging it. The indicator LED on the button should rainbow cycle while rebooting.

Items in stock

  • 1x Connected Launchpads
  • 3x 40A SSRs - please don't use
  • 3x RFID Readers
  • 0x RGB LED arcade buttons